An interstitial space is an intermediate space located between regular-use floors, commonly located in hospitals and laboratory-type buildings to allow space for the mechanical systems of the building. By providing this space, laboratory and hospital rooms may be easily rearranged throughout their lifecycles and therefore reduce lifecycle cost. ==Description==
An interstitial space is useful when the mechanical system of the building is highly sophisticated and changing the space on the primary floors is a distinct possibility. The heights of these spaces are generally six to eight feet and allow easy access for repair or alteration.〔Hospital and Healthcare Facility Design: 2nd Edition. Richard L. Miller and Earl S. Swensson. W W Norton & Co Inc., 2002, pp. 51–52〕 If changes or maintenance need to be performed in the interstitial space, the primary space does not need to be shut down, which is important in buildings like hospitals where the equipment in the space must operate constantly. Unlike traditionally built buildings, where the mechanical space is located in the basement or on the top floor, the interstitial space needs few vertical penetrations and therefore leaves more open space on the primary floor. The entire floor plan of these buildings can be more open because there are fewer fixed vertical penetrations through the floor and walls. Another way to use an interstitial space is to incorporate a design that divides the functions of the building into groups and localizes them. The Zeidler Partnership Architects’ (ZPA) design of the William Osler Health Centre (WOHC) in Brampton, Ontario, is one example of this design. (Note: this was designed but ZPA was not awarded the project.) The groups in this design are based on similar structural and mechanical systems. Flexible design allows for easy expansion or redesign in the future. Horizontal expansion is especially easy because of the interstitial space between the surgical suite and the emergency floors, where the mechanical system functions are the most crucial in this building. Double floor height is used to maintain the horizontal flow of connections throughout the rest of the building without causing any interference with other building systems.
抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)』 ■ウィキペディアで「Interstitial space (architecture)」の詳細全文を読む
スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース |
Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.
|
|